TCDS0301-XTW
EXPIREDAbbott TriClip G4 XTW Clip Delivery System for Transcatheter Edge-to-Edge Repair (TEER)
$19,759.01each
- Available
- 2
- Manufacturer
- Abbott
- Category
- Heart
- Shipping
- $20 per unit in the US, quoted elsewhere
Expired item: sterility not guaranteed, not for human use. It may only be purchased for research, veterinary, or educational purposes.
Description
Abbott TCDS0301-XTW TriClip G4 NT Clip Delivery System The Abbott TriClip™ G4 XT Delivery System (TCDS0301-XTW) is part of the TriClip™ G4 Transcatheter Edge-to-Edge Repair (TEER) System, designed for treating symptomatic severe tricuspid regurgitation (TR) in patients at intermediate or greater surgical risk. This minimally invasive system enables precise navigation and stable delivery of the XT implant, which features extended grasping arms for engaging more leaflet tissue and accommodating larger coaptation gaps. The XTW delivery system facilitates effective leaflet approximation while minimizing the need for open-heart surgery. Product Code: TCDS0301-XTW XTW Delivery System Abbott Structural Heart TriClip Options TCG40100: TriClip G4 System TCDS0301-NT: TriClip G4 NT Delivery System TCDS0301-NTW: TriClip G4 NTW Delivery System TCDS0301-XT: TriClip G4 XT Delivery System TCDS0301-XTW: TriClip G4 XTW Delivery System Required Accessories (Not Included) SZR07: Stabilizer LFT07: Lift PLT07: Support Plate Features Designed for transcatheter tricuspid valve repair Enables real-time positioning and repositioning to optimize TR reduction Compatible with femoral venous access No pre-procedural CT required Fast recovery times; many patients go home the next day Sterilization Device Packaged as Sterile: Yes Requires Sterilization Prior to Use: No Single-Use, Disposable Additional Details Brand: Abbott / St. Jude Medical Category: Structural Heart / Transcatheter Valve Repair Type: Delivery System FDA Product Code: NPS FDA Product Code Name: Tricuspid valve repair device, percutaneously delivered GMDN Term Code: 57790 GMDN Term Name: Heart Valve Clip GMDN Term Definition: An implantable device intended for the reconstruction of an insufficient mitral and/or tricuspid heart valve and reduction of valve regurgitation through the fixed approximation of the valve leaflets. It is typically implanted using a percutaneous clip delivery system (CDS) guided by echocardiographic and fluoroscopic imaging. It is typically made of implant grade metal alloys with a polyester fabric cover. Disposable devices associated with implantation (e.g., CDS and accessories) may be included.
