PTS-0607-7F135
EXPIREDSurmodics Pounce 7F Thrombectomy Device 135cm
$4,558.48each
- Available
- 6
- Manufacturer
- Surmodics
- Category
- Thrombectomy
- Shipping
- $20 per unit in the US, quoted elsewhere
Expired item: sterility not guaranteed, not for human use. It may only be purchased for research, veterinary, or educational purposes.
Description
Surmodics Pounce Thrombectomy System The Pounce thrombectory system is intended for the nonsurgical removal of thrombi and emboli from the peripheral arterial vasculature in vessels 3.5 to 6 mm in diameter. The Pounce LP, a new addition to the Pounce platform, is indicated for use in vessels ranging from 2 to 4 mm in diameter, sizes typical of vessels found below the knee. Product Code: PTS-0607-7F135 Sheath Compatibility: 7F Guidewire Compatibility: 0.035" (0.889mm) Working Length: 135cm Basket Diameter: 6mm Funnel Diameter: 7mm Delivery Catheter Working Length: 135cm Delivery Catheter Proximal Diameter: 0.074" (1.88mm) Delivery Catheter Distal Diameter: 0.064" (1.62mm) Basket Wire Working Length: 300cm Wire Outer Diameter: 0.026" (0.66mm) Basket Outer Diameter: 6mm Basket Length: 4.5cm Tip Length: 3.4cm Funnel Catheter Working Length: 120cm Funnel Length: 6.5cm Funnel Outer Diameter: 7mm The Pounce mechanical thrombectomy device is designed to promptly remove organized thrombus or embolus without the need for capital equipment, thrombolytics, or aspiration. The system is composed of three components: a 5-F delivery catheter, a basket wire, and a funnel catheter. The basket wire is delivered distal to the location of the thrombus, deploying two nitinol self-expanding baskets. The baskets capture the clot and are retracted into the nitinol collection funnel. With the clot entrained, the system is withdrawn into a minimum 7-F guide sheath through which the clot is removed from the body Sterilization Device Packaged as Sterile: Yes Requires Sterilization Prior to Use: No Single-Use Disposable Additional Details Company Name: Surmodics, Inc. FDA Product Code: QEW FDA Product Code Name: Peripheral Mechanical Thrombectomy With Aspiration GMDN Term Code: 58173 GMDN Term Name: Thrombectomy suction catheter GMDN Term Definition: A flexible or semi-flexible tube designed for the percutaneous, transluminal disruption and removal of clotted blood (i.e., a thrombus or thromboembolus) or other formed elements causing vascular obstruction in native/stented blood vessels, native/synthetic bypass grafts, and/or haemodialysis access grafts, through suction (aspiration) in conjunction with a syringe or dedicated suction pump system (pump not included). It may additionally be intended for infusion of fluids and/or used as a guide-catheter to facilitate introduction of a thrombectomy wire-net (not included) to remove residual thrombus. Collection containers may be included with the catheter. This is a single-use device.
