Alto Medical
Search BEQ-HLS-7050-USA
MaquetNo photo

BEQ-HLS-7050-USA

EXPIRED

Maquet HLS Set Advance 7.0, Bioline Coating, Standard

$8,130.48each

Available
2
Manufacturer
Maquet
Shipping
$20 per unit in the US, quoted elsewhere

Expired item: sterility not guaranteed, not for human use. It may only be purchased for research, veterinary, or educational purposes.

Description

Getinge Maquet HLS Set Advance for Cardiopulmonary Bypass The HLS Module Advanced is a hollow fiber membrane oxygenator with diffusion membrane, heat exchanger and integrated centrifugal pump. The centrifugal pump pumps the blood into the oxygenator. The oxygenator essentially consists of two membrane packages. The first chamber contains the plastic fibers of the heat exchanger and the oxygenation fibers arranged in crosswise mats. The second chamber contains solely mats made of oxygenation fibers. The blood can be cooled or warmed, as required, by means of the integral heat exchanger. The gas transfer rates are designed for treating patients within this blood flow range. If treating patients of smaller sizes, always take into account the relatively higher hemodilution due to the priming volume. Three pressure sensors and a temperature sensor are integrated in the HLS Module Advanced. The venous measuring cell can be used to measure venous oxygen saturation, hemoglobin, hematocrit and venous temperature. Product Code: BEQ-HLS 7050-USA Blood Flow: 0.5-7 l/min Coating: Bioline Coating HLS Set Advanced 7.0 Sterilization Device Packaged as Sterile: Yes Requires Sterilization Prior to Use: No Single-Use Disposable Additional Details Company Name: Maquet Cardiopulmonary AG FDA Product Code: DTZ FDA Product Code Name: Oxygenator, Cardiopulmonary Bypass FDA Product Code: KFM FDA Product Code Name: Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type FDA Product Code: DTR FDA Product Code Name: Heat-Exchanger, Cardiopulmonary Bypass GMDN Term Code: 35441 GMDN Term Name: Cardiopulmonary bypass system blood tubing set GMDN Term Definition: A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.

Other listings of BEQ-HLS-7050-USA