3MAXC-SD
EXPIREDPenumbra 3MAX Reperfusion Catheter 160cm
$1,215.98each
- Available
- 9
- Manufacturer
- Penumbra
- Expiry
- 03-2027
- Category
- Thrombectomy
- Shipping
- $20 per unit in the US, quoted elsewhere
Expired item: sterility not guaranteed, not for human use. It may only be purchased for research, veterinary, or educational purposes.
Description
Penumbra 3MAX Reperfusion Catheter The Penumbra System® 3MAX® Reperfusion Catheter is a sterile, single-use aspiration catheter designed to deliver continuous aspiration directly to thrombus within the neurovasculature. As part of the Penumbra System, it is indicated for revascularization of patients with acute ischemic stroke caused by intracranial large-vessel occlusion. Its 160 cm working length, tapered shaft and lumen profile support navigation into smaller, distal cerebral vessels. A hydrophilic coating facilitates advancement through tortuous anatomy, while a radiopaque marker band supports fluoroscopic visualization during positioning. Product Code: 3MAXC Product type: Neurovascular reperfusion and aspiration catheter Working length: 160 cm Proximal outer diameter: 4.7 F, 1.57 mm (0.062 inch) Distal outer diameter: 1.27 mm (0.050 inch) Proximal inner diameter: 1.09 mm (0.043 inch) Distal inner diameter: 0.89 mm (0.035 inch) Guidewire compatibility: 0.36 mm (0.014 inch) Coating: Hydrophilic Visualization: Radiopaque marker band Supplied accessories: Steam-shaping mandrel, rotating hemostasis valve and peelable sheath Latex information: Not made with natural rubber latex Sterility: Sterile and non-pyrogenic Usage: Single-use Compatible aspiration source: Penumbra aspiration pump system Additional Details Company Name: Penumbra FDA Product Code: NRY FDA Product Code Name: Catheter, Thrombus Retriever GMDN Term Code: 58173 GMDN Term Name: Thrombectomy Suction Catheter GMDN Term Definition: A flexible or semi-flexible tube designed for the percutaneous, transluminal disruption and removal of clotted blood (i.e., a thrombus or thromboembolus) or other formed elements causing vascular obstruction in native/stented blood vessels, native/synthetic bypass grafts, and/or haemodialysis access grafts, through suction (aspiration) in conjunction with a syringe or dedicated suction pump system (pump not included). It may additionally be intended for infusion of fluids and/or used as a guide-catheter to facilitate introduction of a thrombectomy wire-net (not included) to remove residual thrombus. Collection containers may be included with the catheter. This is a single-use device.
